EDC15C4

Notes for different solutions

DTC: NO UNPLUGS REQUIRED
EGR: *IMPORTANT*  ACTUATOR PLUG MUST BE DISCONNECTED
Hardcut Popcorn: RPM SET-POINT IS AT 4502
Hot Start: NO UNPLUGS REQUIRED